Cisco Redundant Power System 2300 Manual
Fotostation 6.0 crack. Cisco Redundant Power System 2300. The Cisco RPS 2300 supplies redundant power for up to two of six connected 48-port PoE devices in a convenient.
The Cisco ® Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and resiliency for a variety of power requirements, including Power over Ethernet (PoE). It helps ensure uninterrupted operation and protection against device power supply failures by providing seamless failover for Cisco switches such as the Cisco Catalyst ® 2960-X, 2960-Plus, 2960-S, 2960, and 3750-E Series Switches and routers such as the Integrated Services Routers. The Cisco RPS 2300 supplies redundant power for up to two of six connected 48-port PoE devices in a convenient, 1-rack-unit form factor (Figure 1).
When attached to Cisco Catalyst 2960-X, 2960-S, 3750-E, 3560-E Series and Meraki Switches, the Cisco RPS 2300 offers additional intelligent management capabilities. Cisco RPS 2300 Flexibility and High Availability The Cisco RPS 2300 can provide complete internal power supply redundancy for up to two attached networking devices. It has two power supply bays and can accept 1150W AC or 750W AC power supply modules. These power supply modules are also used with Cisco Catalyst 2960-X, 2960-Plus, 2960-S, 2960, 3750-E, 3560-E Series and Meraki Switches. With two 1150W AC power supply modules, the Cisco RPS 2300 can fully back up two 48-port switches that are delivering 15.4W of PoE on all ports. The Cisco RPS 2300 also has a replaceable fan module.
10/100 IP Phone and Desktop Computer Connections When designing or upgrading a wiring closet, careful consideration should be given to power requirements, particularly for PoE deployments. A power architecture can be selected based on the level of availability desired. The primary power faults to protect against include: ● Internal power supply failures in network devices ● Failure of an AC circuit (a circuit breaker tripping, for example) ● Interruption of utility power The Cisco RPS 2300 can address the first two issues. The last issue requires an uninterruptible power supply (UPS). With a single AC circuit, regardless of whether it is from a UPS (Figure 3), the RPS provides protection against a power supply failure for up to two attached devices.
With a second circuit (Figure 4), again regardless of whether it is from a UPS, the RPS provides protection not only from an internal power supply failure but also a failure of the primary AC source. For maximum availability, the RPS should always be used in conjunction with a UPS (Figure 5). Using the Cisco RPS 2300 and Connected Network Devices with a UPS for Maximum Availability Features and Benefits High Availability/Increased Network Uptime ● Modular power supplies and a fan module offer enhanced availability.
● The system supports traditional data-only Ethernet switches as well as PoE switches. ● The system is capable of providing AC source backup when separate circuits are used for the RPS and attached devices.
Ease of Use and Ease of Deployment ● Modular power supplies offer configuration flexibility. ● The system, or individual RPS ports, can be remotely placed in active or standby mode. ● 1-rack-unit form factor provides for efficient wiring closet space utilization ● The system offers configurable RPS port priorities and failover policy. Applications: ◦ Switch connectivity and power requirements ◦ Power delivery status for individual RPS ports ◦ Net power usage ◦ Backup, failure, and exception history ● The system enables hot insertion of external devices and modular power supplies ● LEDs on front panel and power supplies indicate system and power status.
Cost-Effective Solution ● Innovative power architecture delivers a cost-effective RPS that can connect up to six devices and can actively back-up up to two devices simultaneously, thereby reducing the redundant power cost per device. ● The system supports a wide variety of Cisco Catalyst fixed configuration switches and Cisco Integrated Services Routers. Description Specification C3K-PWR-1150WAC C3K-PWR-750WAC Maximum output power 1150W 750W Input-voltage range and frequency 115-240 VAC, 50-60 Hz 100-240 VAC, 50-60 Hz Input current 12-6A 10-5A Output ratings 12V@25A and -52V@16.4A 12V@25A and -52V@8.7A Output holdup time 20 ms minimum 20 ms minimum Power-supply input receptacles IEC 320-C13 (IEC60320-C13) IEC 320-C13 (IEC60320-C13) Power cord rating 15A 15A LED indicators “AC OK” - Input power to the power supply is working properly “PS OK” - Output power from the power supply is working properly Table 3 is a power supply compatibility matrix. Power Supply Compatibility Matrix. Product Specifications Power Supply C3K-PWR-1150WAC C3K-PWR-750WAC Physical specifications H x W x D: 1.65 x 6.0 x 14.90 in.
(4.2 x 15.24 x 37.85 cm) Weight: 5.6 lb (2.6 kg) H x W x D: 1.65 x 6.0 x 11.4 in. (4.2 x 15.24 x 28.96 cm) Weight: 3.9 lb (1.8 kg) Total input BTU (1000 BTU/Hr = 290W) 3924 BTU/Hr, 1150W 4225 BTU/Hr, 765W Operating temperature 23 to 113°F (-5 to 45°C) Storage temperature -4 to 149°F (-20 to 65°C) Relative humidity operating, noncondensing 10 to 85% noncondensing Relative humidity nonoperating, noncondensing 0 to 95% noncondensing Operating altitude 10,000 ft. (3000 m) (up to 45°C) Storage altitude 15,000 ft.
(4570 m) Mean time between failure (MTBF) Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is 500,000 hrs (with 90% confidence level) Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is 500,000 hrs (with 90% confidence level) Electromagnetic compatibility certifications. Dimensions and Weights Without any power supplies H x W x D: 1.75 x 17.5 x 17.15 in. (4.5 x 44.5 x 43.6 cm) Height: 1 RU Weight: 10.8 lb (4.9 kg) With two C3K-PWR-1150WAC power supplies H x W x D: 1.75 x 17.5 x 20.6 in. (4.5 x 44.5 x 52.3 cm) Height: 1 RU Weight: 22 lb (10 kg) With one C3K-PWR-1150WAC power supply H x W x D: 1.75 x 17.5 x 20.6 in.
(4.5 x 44.5 x 52.3 cm) Height: 1 RU Weight: 16.4 lb (7.4 kg) With two C3K-PWR-750WAC power supplies H x W x D: 1.75 x 17.5 x 17.15 in. (4.5 x 44.5 x 43.6 cm) Height: 1 RU Weight: 18.6 lb (8.5 kg) With one C3K-PWR-750WAC power supply H x W x D: 1.75 x 17.5 x 17.15 in. (4.5 x 44.5 x 43.6 cm) Height: 1 RU Weight: 14.7 lb (6.7 kg) Connectors and Cabling Cisco RPS 2300 to external device connection: ● 4.9 ft. (1.5 m) RPS cable ● A 22-pin connector on the RPS end, and two varieties of connectors on the switch end: ◦ 22-pin connector for Cisco Catalyst 3750E/3560E, 3750v2/3560v2, 2960/2960S/2960P/2960X Series Switches and 2911/2921/2951 routers (CAB-RPS2300-E=) ◦ 14-pin connector for all other Cisco networking devices (CAB-RPS2300=) ● The Cisco RPS 2300 comes with one cable of either variety; others must be ordered separately Cisco RPS 2300 power cable connection: ● With the C3K-PWR-1150WAC and the C3K-PWR-750WAC power supply, users get a 15A cable, 6 ft. (1.82 m) in length ● Country-specific cables can be ordered as options Fans The Cisco RPS 2300 has a field-replaceable fan module (BLWR-RPS2300=).
● Fan module dimensions: 1.65 x 6.0 x 11.9 in.
. For translations of the safety warnings that appear in this publication, see the Regulatory Compliance and Safety Information for the Catalyst 3750-E and Catalyst 3560-E Switch or the Cisco RPS 2300 Hardware Installation Guide that shipped with the product and that are also available on Cisco.com. For more information about which RPS 2300 power supply modules to use for specific switch support, see the Cisco Redundant Power System 2300 Hardware Installation Guide. Product Overview Figure 1 Figure 3 show the power supply modules.
Figure 1 1150-W AC Power Supply Module A C O K PS O K 1150-W AC power supply module AC power connector AC OK LED Cooling fans PS OK LED Extraction handle Captive screw Figure 2. Product Overview Figure 3 265-W DC Power Supply Module F R U C C D C IN 2 6 5 W P S O K IN P U T -3 6 to -7 /1 2A O U TP U 26 5W M /2 2A 265-W DC power supply module Captive screws. Power Supply Module Installation Power Supply Module Installation This section describes how to remove and install a new or replacement power supply module in Catalyst 3750-E and Catalyst 3560-E switches, or an RPS 2300. See these sections: Tools and Equipment, page 5. Power Supply Module Installation Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed Warning circuitry could constitute an energy hazard.
Statement 206 Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Warning Statement 1030 Do not work on the system or connect or disconnect cables during periods of lightning activity. Power Supply Module Installation Figure 5 Inserting an AC-Power Supply into an RPS 2300 100- 240 10-5 A AC OK DC OK 50-6 0 HZ 100- 240 10-5 A Ci sc o RP 50-6 0 HZ STD BY DC OU TP S 24 50 AC TIV E TEM P. Power Supply Module Installation Installing a DC-Power Supply (Only Catalyst 3750-E and 3560-E Switches) To connect the switch to a DC-input power source, follow these steps: Preparing for Installation, page 8 Grounding the Switch, page 9 Installing the DC Power Supply in the Switch, page 10 Wiring the DC-Input Power Source, page 11 An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Power Supply Module Installation Grounding the Switch Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.
Statement 1024 Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Power Supply Module Installation Use the ground screw to attach the single-ground lug and wire assembly or the dual-ground adaptor to Step 5 the switch rear panel. Using a ratcheting torque screwdriver, torque the ground-lug screw to 60 lbf-in. (960 ozf-in.) (Figure 10). Power Supply Module Installation Use a Phillips screwdriver to loosen the two captive screws at the lower edge that secure the power Step 4 supply module to the switch chassis (Figure 11). Step 5 Remove the power supply module from the power slot by pulling on the extraction handle. Insert the new power supply into the power supply slot, and gently apply pressure while pushing the Step 6 module into the slot.
Power System Wikipedia
Technical Specifications Torque all terminal block screws to 5 lbf-in. (80 ozf-in.). Step 4 Replace the terminal block plastic safety cover, and torque the screw to 10 lbf-in. (160 ozf-in.). Step 5 Move the DC-power source circuit-breaker handles to the ON position. Step 6 Confirm that the power supply DC OK LED is green. Technical Specifications Table 5 AC-Power Supply Module Power Specifications (continued) Input current C3K-PWR-1150WAC:12–6 A C3K-PWR-750WAC: 10–5 A C3K-PWR-265WAC: 5–2.5 A Output ratings C3K-PWR-1150WAC: 12 V@25 A, –52 V @ 16.4 A C3K-PWR-750WAC: 12 V@25 A, –52 V @ 8.75 A C3K-PWR-265WAC: 12 V@22 A Total input BTU C3K-PWR-1150WAC: 4725 Btus per hour, 1385 W.
You can order printed copies of documents with a DOC-xxxxxx= number. For more information, see the “Obtaining Documentation” section on page These documents provide complete information about the switch and are available on Cisco.com: Regulatory Compliance and Safety Information for the Catalyst 3750-E and Catalyst 3560-E Switch. The DVD enables you to access multiple versions of installation, configuration, and command guides for Cisco hardware and software products. With the DVD, you have access to the same HTML documentation that is found on the Cisco website without being connected to the Internet. We encourage you to use Pretty Good Privacy (PGP) or a compatible product (for example, GnuPG) to encrypt any sensitive information that you send to Cisco.
PSIRT can work with information that has been encrypted with PGP versions 2.x through 9.x. Cisco engineer. The TAC Service Request Tool is located at this URL: For S1 or S2 service requests, or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly. Cisco products that are sold through channel partners. It is updated twice a year and includes the latest Cisco offerings. To order and find out more about the Cisco Product Quick Reference Guide, go to this URL:.
Join a discussion at this URL:. World-class networking training is available from Cisco.
Power System Engineering
You can view current offerings at this URL: Installation Notes for Catalyst 3750-E, Catalyst 3560-E Switches and RPS 2300 Power Supply Modules. CCVP, the Cisco Logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco.